Search results for "skin brachytherapy"

showing 3 items of 3 documents

Dosimetric characteristics of a new unit for electronic skin brachytherapy

2013

PURPOSE: Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachytherapy with the reduced shielding requirements and targeted energy of low energy X-rays. Recently, the Esteya(®) Electronic Brachytherapy System (Esteya EBS, Elekta AB-Nucletron, Stockholm, Sweden) has been developed specifically for HDR brachytherapy treatment of surface lesions. The system provides rad…

Original Paperelectronic brachytherapybusiness.industrymedicine.medical_treatmentTreatment durationSuperficial radiotherapyBrachytherapyElectronic skinsuperficial radiotherapyRadiation therapyLow energyOncologynonmelanoma skin-cancermedicineskin brachytherapyRadiology Nuclear Medicine and imagingNuclear medicinebusinessDose rateDepth doseJournal of Contemporary Brachytherapy
researchProduct

Depth determination of skin cancers treated with superficial brachytherapy: ultrasound vs. histopathology

2014

Purpose: The purpose of this study is to compare high frequency ultrasonography (HFUS) and histpathologic assessment done by punch biopsy in order to determine depth of basal cell carcinoma (BCC), in both superficial and nodular BCCs prior to brachytherapy treatment. Material and methods: This study includes 20 patients with 10 superficial and 10 nodular BCCs. First, punch biopsy was done to confirm the diagnosis and to measure tumour depth (Breslow rate). Subsequently, HFUS was done to measure tumour depth to search for correlation of these two techniques. Results: Neither clear tendency nor significance of the punch biopsy vs. HFUS depth determination is observed. Depth value differences …

Original Papermedicine.medical_specialtyPunch Biopsyskin cancerelectronic brachytherapyultrasoundbusiness.industrymedicine.medical_treatmentBrachytherapyUltrasoundpunch biopsyPlanning target volumemedicine.diseaseSurgerybasal cell carcinomaOncologymedicineSmall LesionHigh frequency ultrasonographyskin brachytherapyRadiology Nuclear Medicine and imagingHistopathologyBasal cell carcinomaNuclear medicinebusinessJournal of Contemporary Brachytherapy
researchProduct

Dosimetric evaluation of internal shielding in a high dose rate skin applicator

2011

Purpose: The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of this work was to evaluate the dose enhancement from potential backscatter and electron contamination due to the shielding. Material and methods: Two methods were used: a) Monte Carlo simulation, performed with the GEANT4 code, 2 cm Valencia applicator was placed on the surface of a water phantom in …

lcsh:Rlcsh:MedicineOriginal Articleskin brachytherapyMonte Carlo methodsfilm dosimetryJournal of Contemporary Brachytherapy
researchProduct